TrueCool® Therapeutic Hypothermia

TRUECOOL® – Targeted Temperature Management System
Therapeutic hypothermia is now recognized as a key approach in the management of critically ill patients requiring targeted temperature control. The TrueCool® system enables precise and automated regulation of body temperature in anesthesia and intensive care units.
- Description
- system components
- avantages
- etudes
- mentions legales
A Complete Solution for Thermal Management of Critically Ill Patients
TRUECOOL® is a Targeted Temperature Management (TTM) medical device designed to accurately and safely cool or warm a patient’s core body temperature.
The system combines an intelligent control unit with thermoregulated blankets and pads, available in both disposable and reusable versions. Using an advanced feedback algorithm based on continuous patient temperature monitoring, TRUECOOL® automatically adjusts the temperature of the circulating water within the cooling or warming devices.
This non-invasive technology is used in intensive care settings to support neuroprotection and optimize the management of patients with severe neurological or cardiovascular conditions.
Main Indications
- Patients following cardiac arrest with return of spontaneous circulation (ROSC)
- Patients suffering from ischemic stroke or intracranial hemorrhage
- Patients with acute brain injury or traumatic brain injury (TBI)
- Newborns with hypoxic-ischemic encephalopathy (HIE)
- Febrile patients requiring precise temperature control
- Patients with accidental hypothermia
- Temperature management during selected interventional and endovascular procedures
- Unité de contrôle TRUECOOL®
- Couvertures et pads thermorégulés compatibles
- Sonde(s) de température selon la version choisie
- Logiciel de pilotage avec modes automatiques et manuels
-
TRUECOOL® Premium
- Écran tactile 10 pouces avec affichage des tendances thérapeutiques
- 3 connexions pour sondes de température (centrale, cutanée et tympanique)
- Précision de mesure : ±0,05 °C
- Réglage de température par incréments de 0,05 °C
- Base de données intégrée avec export des données (CSV)
- Suivi et analyse des thérapies en temps réel
- Écran tactile 7 pouces
- 1 connexion pour sonde de température centrale
- Précision de mesure : ±0,1 °C
- Réglage de température par incréments de 0,1 °C
- Interface simplifiée pour une utilisation rapide et intuitive
- Température de l’eau : 4 °C à 42 °C
- Température patient : 30 °C à 40 °C
- Décontamination antibactérienne de l’eau par UV-C
- Fonctionnement continu 24h/24
- Alarmes visuelles et sonores
- Sécurités électroniques et mécaniques contre la surchauffe et le refroidissement excessif
- Alimentation : 220-240 VAC, 50 Hz
- Capacité du réservoir : 10 litres
- Port USB intégré
- Fonctionnement silencieux (< 50 dB)
- Dimensions : 105 x 50 x 55 cm
- Poids : 66 kg
- Appareil mobile sur roulettes verrouillables
- Contrôle précis et automatisé de la température corporelle centrale
- Solution non invasive adaptée aux environnements de soins critiques
- Refroidissement et réchauffement dans un même dispositif
- Stabilisation intelligente de la température grâce à un algorithme adaptatif
- Amélioration du confort d’utilisation pour les équipes soignantes
- Couvertures et pads conçus pour un contact prolongé avec la peau
- Enregistrement et traçabilité des données thérapeutiques (version Premium)
-
La gestion ciblée de la température (TTM) est recommandée dans plusieurs protocoles de prise en charge des patients critiques, notamment après un arrêt cardiaque avec retour à une circulation spontanée. De nombreuses publications scientifiques ont démontré l’intérêt de l’hypothermie thérapeutique pour la neuroprotection et l’amélioration des résultats neurologiques chez certaines populations de patients.
Une documentation scientifique et bibliographique détaillée peut être fournie sur demande.
- Augmentation de la survie des patients après certaines situations critiques
- Réduction du risque de lésions cérébrales permanentes
- Diminution des lésions ischémiques et des lésions de reperfusion
- Amélioration des résultats neurologiques
- Optimisation de la prise en charge neuroprotectrice en soins intensifs
Description
A Complete Solution for Thermal Management of Critically Ill Patients
TRUECOOL® is a Targeted Temperature Management (TTM) medical device designed to accurately and safely cool or warm a patient’s core body temperature.
The system combines an intelligent control unit with thermoregulated blankets and pads, available in both disposable and reusable versions. Using an advanced feedback algorithm based on continuous patient temperature monitoring, TRUECOOL® automatically adjusts the temperature of the circulating water within the cooling or warming devices.
This non-invasive technology is used in intensive care settings to support neuroprotection and optimize the management of patients with severe neurological or cardiovascular conditions.
Main Indications
- Patients following cardiac arrest with return of spontaneous circulation (ROSC)
- Patients suffering from ischemic stroke or intracranial hemorrhage
- Patients with acute brain injury or traumatic brain injury (TBI)
- Newborns with hypoxic-ischemic encephalopathy (HIE)
- Febrile patients requiring precise temperature control
- Patients with accidental hypothermia
- Temperature management during selected interventional and endovascular procedures
Additional information
| System Components | <strong>Contenu du système</strong> <strong>Versions disponibles</strong> <strong>TRUECOOL® Lite</strong> <strong>Caractéristiques techniques communes</strong> |
|---|---|
| Avantages | <ul> </ul> |
| Études | <ul> <strong>Bénéfices cliniques rapportés</strong> |
| Mentions légales | TRUECOOL® – Système de contrôle ciblé de la température (TTM). Dispositif médical destiné à la gestion contrôlée de la température corporelle des patients en environnement hospitalier. Utilisation réservée aux professionnels de santé formés. Lire attentivement les instructions d’utilisation avant toute mise en œuvre. Les caractéristiques techniques et indications peuvent varier selon le modèle et la configuration choisie. |
| Extra | <style> .accordion-item { .accordion-item:last-child { .accordion-title { .accordion-content { .accordion-content-inner { input[type="checkbox"] { input[type="checkbox"]:checked + .accordion-title + .accordion-content { <div class="custom-text"> <p>Vous souhaitez intégrer une solution d'hypothermie thérapeutique dans votre établissement ? Contactez notre équipe commerciale pour découvrir le système TrueCool®, bénéficier d'une démonstration et obtenir un accompagnement complet à la mise en œuvre et à la formation des utilisateurs.</p> </div> |
| Fabricant | <img src=" https://gamida.fr/wp-content/uploads/2024/02/logo_em_med.jpg"> |
Formation et accompagnement
Vous souhaitez intégrer une solution d'hypothermie thérapeutique dans votre établissement ? Contactez notre équipe commerciale pour découvrir le système TrueCool®, bénéficier d'une démonstration et obtenir un accompagnement complet à la mise en œuvre et à la formation des utilisateurs.