DELTEX TRUEVUE MONITOR

Advanced haemodynamic monitoring
The future of advanced haemodynamic monitoring, with oesophageal Doppler monitoring combined with arterial pressure wave monitoring at the heart of the system.
- Description
- information
- benefits
- legal information
Oesophageal Doppler monitor combined with arterial pressure signal for perioperative fluid management.
Monitor with touch screen to visualise the velocity signal of red blood cells in the descending aorta, time-dependant.
Battery operated.
Continuous Doppler source at 4 MHz.
Connectivity: RS232, USB and Ethernet ports, ABP (Arterial Blood Pressure) jack port for connection to pressure monitors.
Adult use (16 to 99 years) and paediatric use (from 3 kg to 15 kg).
Dimensions and weight: 29 cm / 32 cm / 14 cm. 2.6 kg.
The TrueVue monitor measures cardiac output directly using a Doppler ultrasound probe. In addition, the monitor can retrieve the blood pressure signal and calculate a series of parameters based on the pressure. It is unique in that it uses cardiac output measured by Doppler to calibrate an algorithm for analysing the contour of the pulse pressure wave. This algorithm provides other pressure-based parameters, such as Dynamic Arterial Elastance (EaDyn=Delta PP/Delta SV).
- TrueVue advanced haemodynamic monitor
- Oesophageal Doppler Probes:
- 2 ADULT probes
- DP240: The DP240 probe has a tight armature and a 10-day service life
- I2C: The I2C probe has a flexible armature and a 72-hour operating time
- 1 PAEDIATRIC probe
- KDP: For paediatric patients weighing 3 kg or more.
- Accessories:
- Doppler probe holder: for holding the probe by a clip via the intubation tube
- Adhesive probe holder: for holding the probe using a nasal adhesive clip
- Flow-based haemodynamic measurements: accurate, real-time, beat-by-beat, measurement of preload, afterload and contractility indicators, including stroke volume and cardiac output
- Improved signal acquisition and retention: makes it easier to use
- Doppler-calibrated pulse contour analysis: accurate long-term management of patients from the operating theatre to the intensive care unit
- Combined flow and pressure parameters: better understanding of cardiac function and circulation management
- HD touch screen: intuitive navigation, control and increased user visibility
- Battery powered with carry handle: portable throughout the clinical pathway
Description
Oesophageal Doppler monitor combined with arterial pressure signal for perioperative fluid management.
Monitor with touch screen to visualise the velocity signal of red blood cells in the descending aorta, time-dependant.
Battery operated.
Continuous Doppler source at 4 MHz.
Connectivity: RS232, USB and Ethernet ports, ABP (Arterial Blood Pressure) jack port for connection to pressure monitors.
Adult use (16 to 99 years) and paediatric use (from 3 kg to 15 kg).
Dimensions and weight: 29 cm / 32 cm / 14 cm. 2.6 kg.
The TrueVue monitor measures cardiac output directly using a Doppler ultrasound probe. In addition, the monitor can retrieve the blood pressure signal and calculate a series of parameters based on the pressure. It is unique in that it uses cardiac output measured by Doppler to calibrate an algorithm for analysing the contour of the pulse pressure wave. This algorithm provides other pressure-based parameters, such as Dynamic Arterial Elastance (EaDyn=Delta PP/Delta SV).
Additional information
Information | <ul><li>TrueVue advanced haemodynamic monitor</li><li>Oesophageal Doppler Probes: </li><li>2 ADULT probes <ul><li>DP240: The DP240 probe has a tight armature and a 10-day service life</li><li>I2C: The I2C probe has a flexible armature and a 72-hour operating time</li></ul></li><li>1 PAEDIATRIC probe <ul><li>KDP: For paediatric patients weighing 3 kg or more.</li></ul><li>Accessories:</li><ul><li>Doppler probe holder: for holding the probe by a clip via the intubation tube</li><li>Adhesive probe holder: for holding the probe using a nasal adhesive clip</li></li></ul> |
---|---|
Benefits | <ul><li>Flow-based haemodynamic measurements: accurate, real-time, beat-by-beat, measurement of preload, afterload and contractility indicators, including stroke volume and cardiac output</li><li>Improved signal acquisition and retention: makes it easier to use</li><li>Doppler-calibrated pulse contour analysis: accurate long-term management of patients from the operating theatre to the intensive care unit</li><li>Combined flow and pressure parameters: better understanding of cardiac function and circulation management</li><li>HD touch screen: intuitive navigation, control and increased user visibility</li><li>Battery powered with carry handle: portable throughout the clinical pathway</li></ul> |
Legal information | TrueVue oesophageal Doppler heart function monitor. Class IIb medical device. CE0086. Certification body: BSI. Manufactured by Deltex. Not included in the list of reimbursable products and services provided for in article L165-1 of the French Social Security Code. To ensure correct use of the device,, read the instructions carefully before use. |