The PAJUNK® FuserPump is part of a system for analgesia by Continuous Wound Infiltration and is used with the Pajunk InfiltraLong catheter.

  • 350 ml volume.
  • Variable flow rate using a key (kept separately or integrated into the system): 3, 5, 8 ml/hour.
  • Supplied with a 60 ml syringe for filling, a bag for transport and a patient label for traceability.
    The FuserPump diffuser is available in :
  • Luer 350 ml: 3, 5, 8 ml/h
  • NRFit 350 ml: 3, 5, 8 ml/h
  • Flow rate adjustable from 3, 5 or 8 ml/h
  • 350 ml capacity
  • Transparent for visual inspection
  • Shock-proof
  • Accuracy : +/- 10%(saline solution at room temperature)
  1. Beaussier M,Aissou M. Continuous wound infiltration or intra-articular infusion for postoperative analgesia. Ann Fr Anesth Reanim. 2009 Mar;28(3):e153-62 [Article in French]
  2. Rackelbaum T,Le Strat S,Silvera S,Schmitz T,Bassot A,Goffinet F,Ozier Y,Beaussier M,Mignon A. Improving continuous wound infusion effectiveness for postoperative analgesia after caesarean delivery: a randomized controlled trial. Obstet Gynecol. 2010 Oct;116(4):893-900.
  3. Campolo M.,Molin D.,Rawal N.,Soldati A. Protocols to compare infusion distribution of wound catheters,Med. Eng. Phys. 2011 Apr;34(3): 326-332.
4379

Description

The PAJUNK® FuserPump is part of a system for analgesia by Continuous Wound Infiltration and is used with the Pajunk InfiltraLong catheter.

  • 350 ml volume.
  • Variable flow rate using a key (kept separately or integrated into the system): 3, 5, 8 ml/hour.
  • Supplied with a 60 ml syringe for filling, a bag for transport and a patient label for traceability.

Additional information

Information

<ul>
The FuserPump diffuser is available in :
<li>Luer 350 ml: 3, 5, 8 ml/h</li>
<li>NRFit 350 ml: 3, 5, 8 ml/h</li></ul>

Benefits

<ul><li>Flow rate adjustable from 3, 5 or 8 ml/h</li><li>350 ml capacity</li><li>Transparent for visual inspection</li><li>Shock-proof </li><li>Accuracy : +/- 10%(saline solution at room temperature)</li></ul>

Studies

<ol start="1"><li>Beaussier M,Aissou M. Continuous wound infiltration or intra-articular infusion for postoperative analgesia. Ann Fr Anesth Reanim. 2009 Mar;28(3):e153-62 [Article in French]</li><li>Rackelbaum T,Le Strat S,Silvera S,Schmitz T,Bassot A,Goffinet F,Ozier Y,Beaussier M,Mignon A. Improving continuous wound infusion effectiveness for postoperative analgesia after caesarean delivery: a randomized controlled trial. Obstet Gynecol. 2010 Oct;116(4):893-900.</li><li>Campolo M.,Molin D.,Rawal N.,Soldati A. Protocols to compare infusion distribution of wound catheters,Med. Eng. Phys. 2011 Apr;34(3): 326-332.</li></ol>

Fabricant

<img src="https://gamida.fr/wp-content/uploads/2024/02/logo_pajunk.jpg"&gt;

Traduction_FR

4379

    You may also like…

    CONTACT US

      To read our policy on the use of your personal data, click here.